Artificial Joint Manufacturing
Custom Systems
Aerotech designs and manufactures custom systems to your specifications.
Available in ball-screw-driven (ATS) or linear motor drive (ALS)
Optimized cable management systems
Complete engineering support
Variety of feedback and control options to meet
your needs
Aerotech’s custom five-axis
system used in the production of a
hip joint Ňshaving” instrument.
shaping instrument detailed above. A five-axis system
Acetabular Joint Forming
consisting of three linear axes and two rotary axes is used to
Hip implant surgery involves replacing the acetabulum and
position the hemisphere-shaped instrument for cutting with a
femoral head that comprise the hip joint with a synthetic
laser. The shape of the cutting edges of the instrument are
device. As there is a wide variation in bone structure among
complex in form and creation of the motion program is
replacement patients, the joint must be shaped or formed to
further complicated as these shapes must be projected onto a
accept the profile of the mating replacement socket. This
spherical surface. A third-party 3D CAD/CAM program was
shaping is accomplished by Ňshaving” bone material from
used to generate the desired tool path along the surface of the
the socket area (acetabulum). To provide a consistent form
hemisphere. The A3200's ability to execute standard G-code-
on the mating-bone surface, joint replacement manufacturers
type programs provides a ready-made interface to accept the
supply a hemispherical Ňshaving” device whose diameter is
tool path output from CAD/CAM programs. For this
consistent with that of the synthetic acetabulum to be
application the A3200 operated in ŇInverse Time” mode,
implanted. This instrument has a series of projected cutting
which provides a means of ensuring a constant surface speed
edges that are placed in a
when executing the complex geometry on the surface of the
spiral fashion along the
hemisphere. In ŇInverse Time” mode the CAD/CAM
surface. These cutting
program calculates the path distance for each block and
edges have some degree
encodes this information on the G-code program line. This
of overlap so that bone
distance is then used by the A3200 controller to calculate a
material is removed
constant surface speed along the programmed path ensuring
around the entire surface
consistent results on all regions of the part.
of the mating socket as the
device is rotated. After the
A combination of direct drive and screw-driven stages were
instrument has been used
used within the system. ALS5000 linear motor stages were
to shape the bone, the
A hemisperical Ňshaving”
chosen for the X and Y axes due to their high stiffness,
socket is ready to accept
device is used to shape the hip
throughput, and load carrying capability. Screw-driven axes
the insertion of the
socket prior to insertion of the
were used for the rotary and vertical axes to counteract
synthetic replacement
synthetic replacement joint.
forces induced by gravity and offset fixtures. Special
joint.
shrouding was applied to the cable management of the X and
Y axes to provide protection from the debris generated as a
Aerotech has provided motion equipment to joint
byproduct of the cutting process.
replacement suppliers to manufacture the acetabulum-
Aerotech at a
Glance

Aerotech Timeline
Success in Laser Processing

Laser Edge Control
Laser Edge Control - Position Synchronized Output

Laser Edge Mechanics
Laser Edge Direct-
Drive Linear Stages

Laser Edge Drect-Drive Rotary Stages

Linear Translation Stages

Rotary Translation Stages

Engineered Systems
Medical and Life Sciences Industry

High-Speed Cylindrical Laser Cutting Systems

IOL and Contact Lens Manufacturing

DNA Sequencing and Proteome Research

Laser Seam Welding
Artificial Joint Manufacturing