| Type |
Isolation |
| AC Input Configurations |
100
VAC, 115 VAC, 200 VAC, 230 VAC |
| Peak AC Input Inrush Current |
32
Apk |
200
Apk |
| Operating Frequency |
50/60
Hz |
| Maximum Continuous Transformer Output Power |
300
watts max @ 20°C |
500
watts max @ 20°C |
| Peak Transformer Output Power |
400
watts max @ 20°C |
800
watts max @ 20°C |
| Short Circuit/Over Current Protection |
AC
input 10 A breaker/switch (supplementary protection only);
100 VAC/115 VAC configurations contain 4 A slow-blow fuse
connected to transformer primary winding; 200 VAC/230 VAC
configurations contain 3 A slow-blow fuse connected to transformer
primary winding |
AC
input 10 A breaker/switch (supplementary protection only);
100 VAC/115 VAC configurations contain 8 A slow-blow fuse
connected to transformer primary winding; 200 VAC/230 VAC
configurations contain 4 A slow-blow fuse connected to transformer
primary winding |
| Thermal Protection |
Integral
transformer thermal switch is normally closed.
Thermal
switch opens when internal temperature of
transformer
reaches 110°C. |
Integral
transformer thermal switch is normally closed.
Thermal
switch opens when internal temperature of
transformer
reaches 110°C. |
| Secondary Winding Configuration |
28
VAC (40 VDC bus); 56 VAC (80 VDC bus) |
28
VAC (40 VDC bus); 56 VAC (80 VDC bus); 112 VAC (160 VDC bus) |
| +12 VDC Output |
1
A max |
1
A max |