| Output Voltage (1) |
VDC |
40-320(2) |
| Peak Output Current |
Apk |
10 |
20 |
30 |
50 |
75 |
100 |
| Continuous Output Current |
Apk |
5 |
10 |
15 |
25 |
37 |
50 |
| Peak Output Power |
W |
2,720 |
5,440 |
8,160 |
13,600 |
20,160 |
28,800 |
| Continuous Output Power |
W |
1,360 |
2,720 |
4,080 |
6,800 |
10,080 |
14,400 |
| Power Amplifier Bandwidth |
kHz |
2 |
| PWM Switching Frequency |
kHz |
20 |
| Minimum Load Inductance |
mH |
0.8 @ 160 VDC
(1 mH @ 320 VDC) |
| Operating Temperature |
°C |
0 to 50 |
| Storage Temperature |
°C |
-30 to 85 |
| Weight |
kg (lb) |
1.1 (2.5) |
3.9 (8.5) |
5.7 (12.5) |
| Maximum Shunt Regulator
Dissipation |
W |
40 (optional) |
40 (optional) |
40 |
100 (10 A Ext.) |
| Brushless Operation |
Torque (Current),
Velocity, Dual Phase |
| Brush-Type Operation |
Torque, Velocity |
| Power Input |
28-230 VAC, Single
Phase, 50-60 Hz |
28-230 VAC,
50-60 Hz, 1-3 Phase |
| Protection |
Output Short
Circuit (phase-to-phase and phase-to-ground); Peak Overcurrent,
RMS Overcurrent; DC Bus Overvoltage; Overtemp; Control or
Power Stage Bias Power Supply Undervoltage. Galvanic Isolation
Between Signal and Power Stages. |
| Indicators |
Drive Enable
LED Indicator, Power-ON LED. |
Drive Enable
LED Indicator, Power-ON LED. Fault & Overload LEDs |
Notes: 1.
Depends on AC input voltage
2. 40-80 VDC bus requires external transformer, 110 VAC auxiliary
input for control input power
|