| Performance
Specifications(1,5) |
| Continuous
Force 1.4 bar (20 psi)(2) |
N (lb) |
65.9 (14.8) |
105.5 (23.7) |
135.7 (30.5) |
161.4 (36.3) |
| Continuous
Force, No Air(2)
|
N (lb) |
39.0 (8.8) |
68.2 (15.3) |
93.6 (21.0) |
108.3 (24.4) |
| Peak Force(3) |
N (lb) |
263.7 (59.3) |
422.1 (94.9) |
542.8 (122.0) |
645.6 (145.2) |
| Electrical
Specifications(5) |
| Winding Designation |
|
-A |
-A |
-A |
-A |
| BEMF Constant
(Line-Line, Max) |
V/m/s (V/in/s) |
9.97 (0.25) |
18.66 (0.47) |
26.89 (0.68) |
36.10 (0.92) |
|
Continuous Current 1.4 bar (20 psi)(2) |
Amppk
Amprms |
7.60
5.37 |
6.50
4.60 |
5.80
4.10 |
5.14
3.63 |
| Continuous
Current, No Air(2)
|
Amppk
Amprms |
4.50
3.18 |
4.20
2.97 |
4.00
2.83 |
3.45
2.44 |
| Peak Current,
Stall(3)
|
Amppk
Amprms |
30.40
21.50 |
26.00
18.38 |
23.20
16.40 |
20.56
14.54 |
|
Force Constant, Sine Drive(4,8) |
N/Amppk (lb/Amppk) |
8.67 (1.95) |
16.24 (3.65) |
23.40 (5.26) |
31.40 (7.06) |
|
N/Amprms (lb/Amprms) |
12.27 (2.76) |
22.96 (5.16) |
33.09 (7.44) |
44.41 (9.98) |
| Motor Constant(2,4) |
N/√W (lb/√W) |
4.97 (1.12) |
7.23 (1.63) |
9.03 (2.03) |
10.10 (2.27) |
| Resistance,
25°C (Line-Line) |
ohms |
2.9 |
4.8 |
6.4 |
9.2 |
| Inductance
(Line-Line) |
mH |
0.83 |
1.33 |
1.90 |
3.40 |
| Thermal Resistance 1.4
bar (20 psi) |
°C/W |
0.57 |
0.47 |
0.44 |
0.39 |
| Thermal Resistance (No
Cooling) |
°C/W |
1.62 |
1.12 |
0.93 |
0.87 |
| Maximum Bus
Voltage |
VDC |
340 |
340 |
340 |
340 |
| Mechanical
Specifications |
| Air Flow,
20 psi |
m3/s
(SCFM) |
1.3x10-3
(2.9) |
1.7x10-3
(3.6) |
1.4x10-3
(2.9) |
1.5x10-3
(3.2) |
| Coil Weight |
kg (lb) |
0.16 (0.35) |
0.26 (0.57) |
0.34 (0.75) |
0.52 (1.14) |
| Coil Length |
mm (in) |
91.0 (3.58) |
142.0 (5.59) |
192.0 (7.56) |
267.0 (10.51) |
| Heat Sink |
mm
(in) |
250x250x25 (10x10x1) |
250x250x25 (10x10x1) |
250x250x25 (10x10x1) |
250x250x25 (10x10x1) |
| Magnet Track
Weight |
kg/m (lb/ft) |
9.06 (6.08) |
9.06 (6.08) |
9.06 (6.08) |
9.06 (6.08) |
| Magnetic Pole
Pitch |
mm (in) |
25.00 (0.98) |
25.00 (0.98) |
25.00 (0.98) |
25.00 (0.98) |
Notes:
1. Performance is dependent upon heat sink configuration, system
cooling conditions, and ambient temperature.
2. Values shown @ 100°C rise above a 25°C ambient temperature,
with motor mounted to the specified aluminum heat sink.
3. Peak force assumes correct rms current; consult Aerotech.
4. Force constant and motor constant specified at stall.
5. All performance and electrical specifications ±10%.
6. Maximum winding temperature is 125°C.
7. Ambient operating temperature range 0°C - 25°C. Consult
Aerotech for performance in elevated ambient temperatures.
8. All Aerotech amplifiers are rated Apk; use torque
constant in N-m/Apk when sizing.
|
|
|
|