Performance Specifications(1,5) |
| Continuous Force, 1.4 bar (20 psi)(2) |
N (lb) |
75.1 (16.9) |
120.3 (27.0) |
154.7 (34.8) |
184.0 (41.4) |
| Continuous Force, No Air(2) |
N (lb) |
44.5 (10.0) |
77.7 (17.5) |
106.7 (24.0) |
123.5 (27.8) |
| Peak Force(3) |
N (lb) |
300.6 (67.6) |
481.2 (108.2) |
618.8 (139.1) |
736.0 (165.5) |
Electrical Specifications(5) |
Winding Designation |
|
-A |
-A |
-A |
-A |
| BEMF Constant (Line-Line, Max) |
V/m/s (V/in/s) |
11.37 (0.29) |
21.28 (0.54) |
30.66 (0.78) |
41.15 (1.05) |
| Continuous Current, 1.4 bar, 20 psi(2) |
Amppk
Amprms |
7.60 (5.37) |
6.50 (4.60) |
5.80 (4.10) |
5.14 (3.63) |
| Continuous Current, No Air(2) |
Amppk
Amprms |
4.50 (3.18) |
4.20 (2.97) |
4.00 (2.83) |
3.45 (2.44) |
| Peak Current, Stall(3) |
Amppk
Amprms |
30.40 (21.50) |
26.00 (18.38) |
23.20 (16.40) |
20.56 (14.54) |
| Force Constant, Sine Drive(4,8) |
N/Amppk (lb/Amppk) |
9.89 (2.22) |
18.51 (4.16) |
26.67 (6.00) |
35.80 (8.05) |
N/Amprms (lb/Amprms) |
13.98 (3.14) |
26.17 (5.88) |
37.72 (8.48) |
50.63 (11.38) |
| Motor Constant(2,4) |
N/√W (lb/√W) |
5.67 (1.27) |
8.24 (1.85) |
10.29 (2.31) |
11.52 (2.59) |
| Resistance, 25°C (Line-Line) |
ohms |
2.9 |
4.8 |
6.4 |
9.2 |
| Inductance (Line-Line) |
mH |
0.83 |
1.33 |
1.90 |
3.40 |
| Thermal Resistance, 1.4 bar, 20 psi |
°C/W |
0.57 |
0.47 |
0.44 |
0.39 |
| Thermal Resistance, No Cooling |
°C/W |
1.62 |
1.12 |
0.93 |
0.87 |
| Maximum Bus Voltage |
VDC |
340 |
340 |
340 |
340 |
Mechanical Specifications |
| Air Flow, 20 psi |
m3/s (SCFM) |
1.4x10-3 (2.9) |
1.7x10-3 (3.6) |
1.4x10-3 (2.9) |
1.5x10-3 (3.2) |
| Coil Weight |
kg (lb) |
0.16 (0.35) |
0.26 (0.57) |
0.34 (0.75) |
0.52 (1.14) |
| Coil Length |
mm (in) |
91.0 (3.58) |
142.0 (5.59) |
192.0 (7.56) |
267.0 (10.51) |
| Heat Sink |
mm (in) |
250x250x25 (10x10x1) |
250x250x25 (10x10x1) |
250x250x25 (10x10x1) |
250x250x25 (10x10x1) |
| Magnet Track Weight |
kg/m (lb/ft) |
6.59 (4.42) |
6.59 (4.42) |
6.59 (4.42) |
6.59 (4.42) |
| Magnetic Pole Pitch |
mm (in) |
25 (0.98) |
25 (0.98) |
25 (0.98) |
25 (0.98) |
Notes:
1. Performance is dependent upon heat sink configuration, system cooling conditions, and ambient temperature.
2. Values shown @ 100°C rise above a 25°C ambient temperature, with motor mounted to the specified aluminum heat sink.
3. Peak force assumes correct rms current; consult Aerotech.
4. Force constant and motor constant specified at stall.
5. All performance and electrical specifications ±10%.
6. Maximum winding temperature is 125°C.
7. Ambient operating temperature range 0°C - 25°C. Consult Aerotech for performance in elevated ambient temperatures.
8. All Aerotech amplifiers are rated Apk; use force constant in N/Apk when sizing.
Performance Specifications(1,5) |
| Continuous Force, 1.4 bar (20 psi)(2) |
N (lb) |
54.1 (12.2) |
86.6 (19.5) |
111.4 (25.0) |
132.5 (29.8) |
| Continuous Force, No Air(2) |
N (lb) |
32.0 (7.2) |
56.0 (12.6) |
76.8 (17.3) |
88.9 (20.0) |
| Peak Force(3) |
N (lb) |
216.4 (48.7) |
346.5 (77.9) |
445.5 (100.2) |
529.9 (119.1) |
Electrical Specifications(5) |
Winding Designation |
|
-A |
-A |
-A |
-A |
| BEMF Constant (Line-Line, Max) |
V/m/s (V/in/s) |
8.18 (0.21) |
15.32 (0.39) |
22.07 (0.56) |
29.63 (0.75) |
| Continuous Current, 1.4 bar, 20 psi(2) |
Amppk
Amprms |
7.60 (5.37) |
6.50 (4.60) |
5.80 (4.10) |
5.14 (3.63) |
| Continuous Current, No Air(2) |
Amppk
Amprms |
4.50 (3.18) |
4.20 (2.97) |
4.00 (2.83) |
3.45 (2.44) |
| Peak Current, Stall(3) |
Amppk
Amprms |
30.40 (21.50) |
26.00 (18.38) |
23.20 (16.40) |
20.56 (14.54) |
| Force Constant, Sine Drive(4,8) |
N/Amppk (lb/Amppk) |
7.12 (1.60) |
13.33 (3.00) |
19.20 (4.32) |
25.78 (5.79) |
N/Amprms (lb/Amprms) |
10.07 (2.26) |
18.85 (4.24) |
27.16 (6.11) |
36.45 (8.20) |
| Motor Constant(2,4) |
N/√W (lb/√W) |
4.08 (0.92) |
5.94 (1.33) |
7.41 (1.67) |
8.29 (1.86) |
| Resistance, 25°C (Line-Line) |
ohms |
2.9 |
4.8 |
6.4 |
9.2 |
| Inductance (Line-Line) |
mH |
0.83 |
1.33 |
1.90 |
3.40 |
| Thermal Resistance, 1.4 bar, 20 psi |
°C/W |
0.57 |
0.47 |
0.44 |
0.39 |
| Thermal Resistance, No Cooling |
°C/W |
1.62 |
1.12 |
0.93 |
0.87 |
| Maximum Bus Voltage |
VDC |
340 |
340 |
340 |
340 |
Mechanical Specifications |
| Air Flow, 20 psi |
m3/s (SCFM) |
1.4x10-3 (2.9) |
1.7x10-3 (3.6) |
1.4x10-3 (2.9) |
1.5x10-3 (3.2) |
| Coil Weight |
kg (lb) |
0.16 (0.35) |
0.26 (0.57) |
0.34 (0.75) |
0.52 (1.14) |
| Coil Length |
mm (in) |
91.0 (3.58) |
142.0 (5.59) |
192.0 (7.56) |
267.0 (10.51) |
| Heat Sink |
mm (in) |
250x250x25 (10x10x1) |
250x250x25 (10x10x1) |
250x250x25 (10x10x1) |
250x250x25 (10x10x1) |
| Magnet Track Weight |
kg/m (lb/ft) |
7.11 (4.76) |
7.11 (4.76) |
7.11 (4.76) |
7.11 (4.76) |
| Magnetic Pole Pitch |
mm (in) |
25 (0.98) |
25 (0.98) |
25 (0.98) |
25 (0.98) |
Notes:
1. Performance is dependent upon heat sink configuration, system cooling conditions, and ambient temperature.
2. Values shown @ 100°C rise above a 25°C ambient temperature, with motor mounted to the specified aluminum heat sink.
3. Peak force assumes correct rms current; consult Aerotech.
4. Force constant and motor constant specified at stall.
5. All performance and electrical specifications ±10%.
6. Maximum winding temperature is 125°C.
7. Ambient operating temperature range 0°C - 25°C. Consult Aerotech for performance in elevated ambient temperatures.
8. All Aerotech amplifiers are rated Apk; use force constant in N/Apk when sizing.
|