Continuous Force 1.4 bar (20 psi)(2) |
N (lb) |
31.4 (7.0) |
40.5 (9.1) |
46.9 (10.5) |
58.0 (13.0) |
|
Continuous Force, No Air(2) |
N (lb) |
18.3 (4.1) |
23.0 (5.2) |
30.6 (6.9) |
39.8 (9.0) |
|
Peak Force(3) |
N (lb) |
125.4 (28.2) |
161.9 (36.4) |
187.6 (42.2) |
231.8 (52.1) |
| Electrical Specifications(5)
|
|
Winding Designation |
|
-A |
-A |
-A |
-A |
|
BEMF Constant (Line-Line, Max) |
V/m/s (V/in/s) |
6.80 (0.17) |
9.00 (0.23) |
11.35 (0.29) |
15.90 (0.40) |
|
Continuous Current, 1.4 bar (20 psi)(2) |
Amppk
Amprms |
5.30
3.75 |
5.17
3.66 |
4.75
3.36 |
4.19
2.96 |
|
Continuous Current, No Air(2) |
Amppk
Amprms |
3.10
2.19 |
2.94
2.08 |
3.10
2.19 |
2.88
2.04 |
| Peak
Current, Stall(3) |
Amppk
Amprms |
21.20
14.99 |
20.68
14.62 |
19.00
13.44 |
16.76
11.85 |
|
Force Constant, Sine Drive(4,8) |
N/Amppk (lb/Amppk) |
5.92 (1.33) |
7.83 (1.76) |
9.87 (2.22) |
13.83 (3.11) |
|
N/Amprms (lb/Amprms) |
8.37 (1.88) |
11.07 (2.49) |
13.96 (3.14) |
19.56 (4.40) |
|
Motor Constant(2,4) |
N/√W (lb/√W) |
2.89 (0.65) |
3.35 (0.75) |
3.78 (0.85) |
4.53 (1.02) |
|
Resistance, 25°C (Line-Line) |
ohms |
4.0 |
5.2 |
6.5 |
8.9 |
|
Inductance (Line-Line) |
mH |
0.51 |
0.70 |
0.87 |
1.10 |
|
Thermal Resistance 1.4 bar (20 psi) |
°C/W |
0.85 |
0.69 |
0.65 |
0.61 |
|
Thermal Resistance, No Air |
°C/W |
2.48 |
2.12 |
1.52 |
1.29 |
|
Maximum Bus Voltage |
VDC |
160 |
160 |
160 |
160 |
| Mechanical Specifications
|
|
Air Flow, 20 psi |
m3/s
(SCFM) |
1.5x10-3
(3.12) |
1.5x10-3
(3.15) |
1.5x10-3
(3.22) |
1.5x10-3
(3.12) |
|
Coil Weight |
kg (lb) |
0.10 (0.22) |
0.12 (0.26) |
0.14 (0.31) |
0.20 (0.44) |
|
Coil Length |
mm (in) |
79.0 (3.11) |
95.0 (3.74) |
111.0 (4.37) |
143.0 (5.63) |
|
Heat Sink |
mm
(in) |
250x250x25 (10x10x1) |
250x250x25 (10x10x1) |
250x250x25 (10x10x1) |
250x250x25 (10x10x1) |
|
Magnet Track Weight |
kg/m (lb/ft) |
4.04 (2.71) |
4.04 (2.71) |
4.04 (2.71) |
4.04 (2.71) |
|
Magnetic Pole Pitch |
mm (in) |
16.00 (0.63) |
16.00 (0.63) |
16.00 (0.63) |
16.00 (0.63) |
Notes:
1. Performance is dependent upon heat sink configuration, system
cooling conditions, and ambient temperature.
2. Values shown @ 100°C rise above a 25°C ambient temperature,
with motor mounted to the specified aluminum heat sink.
3. Peak force assumes correct rms current; consult Aerotech.
4. Force constant and motor constant specified at stall.
5. All performance and electrical specifications ±10%.
6. Maximum winding temperature is 125°C.
7. Ambient operating temperature range 0°C - 25°C. Consult
Aerotech for performance in elevated ambient temperatures.
8. All Aerotech amplifiers are rated Apk; use torque
constant in N-m/Apk when sizing.
|
|
|
|