FiberAlign®
90 and 130 Series |
|
|
|
| |
|
| Ordering Example |
|
FA90 |
-25 |
-25 |
-25 |
-R |
-AA |
|
|
Lower Axis
Travel (mm) |
Middle
Axis Travel (mm) |
Vertical
Axis Travel (mm) |
Opt Rotary
Axis 1 |
Orientation |
|
|
-25
-50 |
-25
-50 |
-4
-25 |
-T
-P
-R |
-AA
-AB |
|
FA90 Series Fiber
Translator |
|
FA90
|
Proprietary direct-drive motor technology, linear encoder
based fiber translator. XYZ axes aligned to 10 arc sec
orthogonal.
|
| |
|
| Note:
Requires clean, dry air supply for pneumatic counterbalance
when a vertical axis is specified.
|
|
Linear Stage Travel |
|
-4
|
4 mm (.16 in) travel stage (vertical only)
|
| -25 |
25
mm (1 in) travel stage (vertical or horizontal axis) |
| -50 |
50
mm (2 in) travel stage (horizontal only)
|
|
Optional Rotary Axes
(Opt Rotary Axis 1-3) |
|
For reference purposes the Z axis is considered to be
the middle axis of a three-axis stack, X is the bottom
axis, and Y is the vertical axis.
|
| -T |
Single
"planar" rotary axis oriented as yaw, rotation about Y
axis (ANT-20RA) |
| -P |
Single
"goniometer" rotary axis oriented as pitch, rotation about
X axis (ANT-20G) |
| -R |
Single
"goniometer" rotary axis oriented as roll, rotation about
Z axis (ANT-20G) |
| Note:
For 5- and 6-axis configurations, please consult the factory. |
| Note:
The above sequences represent the only valid rotary axis
combinations.
|
|
Controller Platform |
| -A3200 |
Automation
3200 software-only controller; Npaq® with MXR and
DP32020E amplifiers, cables and software included
|
| See
Motion
Controllers section for specifications.
|
|
Orientation (-AA,
-AB) |
|
The letters in the orientation correspond to the standard
X/Y/Z configurations detailed in Aerotech's PA5 specification.
The first letter indicates the orientation of the two
horizontal axes and the second letter indicates the orientation
of the vertical axes. These two combinations represent
the only two standard configurations.
|
| -AB |
Bottom
axis cable exits rear, middle axis cable exits left, vertical
tabletop parallel to middle axis travel and facing the
front. |
| -AA |
Bottom
axis cable exits rear, middle axis cable exits left, vertical
axis tabletop parallel to bottom axis facing to the right. |
| Ordering Example |
|
FA130 |
-50 |
-50 |
-25 |
-T |
-P |
-R |
-AA |
|
|
Lower Axis
Travel (mm) |
Middle Axis
Travel (mm) |
Vertical
Axis Travel (mm) |
Opt Rotary
Axis 1 |
Opt Rotary
Axis 2 |
Opt Rotary
Axis 3 |
Orientation |
|
|
-25
-50
-100
-150 |
-25
-50
-100
-150 |
-25 |
-T
-P
-R |
-P
-R |
-R |
-AA
-AB
-BA
-BC |
|
FiberAlign 130 Series
Fiber Translator |
|
FA130
|
Direct-drive linear motor, linear-encoder-based fiber translator.
XYZ axes aligned to 5 arc sec orthogonal.
|
| Note:
Requires clean, dry air supply for pneumatic counterbalance
for vertical axis.
|
|
Linear Stage Travel |
|
-25
|
25 mm (1 in) travel stage (vertical axis only)
|
| -50 |
50
mm (2 in) travel stage (horizontal axes only) |
| -100 |
100
mm (4 in) travel stage (horizontal axes only) |
| -150 |
150
mm (6 in) travel stage (horizontal axes only)
|
|
Optional Rotary Axes
(Opt Rotary Axis 1-3) |
|
For reference purposes the "Z" axis is considered to be
the middle axis of a three-axis stack, X is the bottom axis,
and Y is the vertical axis.
|
| -T |
Single
"planar" rotary axis oriented as yaw, rotation about Y axis
(ANT-20RA) |
| -P |
Single
"goniometer" rotary axis oriented as pitch, rotation about
X axis (ANT-20G) |
| -R |
Single
"goniometer" rotary axis oriented as roll, rotation about
Z axis (ANT-20G) |
| -T-P |
Dual
rotary axis, one planar and one goniometer (50 mm radius),
yaw and pitch |
| -T-R |
Dual
rotary axis, one planar and one goniometer (50 mm radius),
yaw and roll |
| -P-R |
Dual
rotary axis, two goniometers (50 mm and 90 mm), pitch and
roll |
| -T-P-R |
Triple
rotary axis, one planar and two goniometers (50 mm and 90
mm), yaw, pitch, and roll |
|
Note: The above sequences represent the only valid rotary
axis combinations.
|
|
Controller Platform |
| -A3200 |
Automation
3200 software-only controller; Npaq® with MXR and DP32020E
amplifiers, cables and software included |
| |
| See
Motion
Controllers section for specifications.
|
|
Orientation (-AA, -AB,
-BA, -BC) |
|
The letters in the orientation correspond to the standard
X/Y/Z configurations detailed in Aerotech's PA5 specification.
The first letter indicates the orientation of the two horizontal
axes and the second letter indicates the orientation of
the vertical axes. These four combinations represent the
only four standard configurations. Combinations AA-BA, AB-BC
can be considered as left- and right-hand orientations of
the same stack, or mirror images of each other.
|
| -AB |
Bottom
axis cable exits rear, middle axis cable exits left, vertical
tabletop parallel to middle axis travel and facing the front. |
| |
| -AA |
Bottom
axis cable exits rear, middle axis cable exits left, vertical
axis tabletop parallel to bottom axis facing to the right. |
| |
| -BA |
Bottom
axis cable exits rear, middle axis cable exits right, vertical
axis tabletop parallel to bottom axis facing to the left. |
| |
| -BC |
Bottom
axis cable exits rear, middle axis cable exits right, vertical
tabletop parallel to middle axis travel and facing the front. |
| |
|
|
|
|