| Total Travel |
100° |
| Bus Voltage |
Up to 160
VDC |
| Motor |
S-180-44-A |
| Continuous
Current |
Apk |
2.7 A |
| Arms |
1.9 A |
| Accuracy(1) |
±9.7 µrad (±2 arc sec) |
| Repeatability
(Bi-Directional) |
±4.85 µrad (±1 arc sec) |
| Resolution(2) |
0.058 µrad
(0.012 arc sec) |
| Maximum
Load (Axial) |
45 kg (100
lb) |
| Maximum
Speed(3) |
60º per second |
|
Rotating Inertia (Unloaded) |
0.1203 kg-m2 (1.072 lb-in-s2) |
| Operating
Pressure(4) |
60 psig (4.137
bar) +0 psig (0 bar) -5 psig (-0.344 bar) |
| Vacuum
Supply |
21 "Hg
±2 "Hg |
| Air
Consumption(5) |
<2 SCFM |
| Mass |
17 kg (37.4
lb) |
| Finish |
Tabletop |
Hardcoat |
| Stage |
Black Anodized |
Notes:
1. Requires Aerotech controller for calibration and parts program
implementation.
2. Based on Aerotech controls using 500X multiplication and controller
quadrature. Higher resolutions available.
3. Maximum speed is load dependent. Maximum application velocity
may be limited by system data rate and resolution.
4. To protect an air bearing against under pressure, an in-line
pressure switch tied to the motion controller is recommended.
5. Air supply must be clean, dry to 0° F dewpoint and filtered
to 0.25 µm or better; recommend nitrogen at 99.9% purity.
6. Specifications are for single-axis systems, measured 50 mm above
the tabletop. Performance of multi-axis systems is payload and workpoint
dependent. Consult factory for multi-axis
or non-standard applications.
|
|
|
|